W3G400-CK13-P3
Manufacturer: EBM-PAPST
(13 reviews)
Description:
EC axial fan - HyBlade
Weight: 10.3 kg
Motor size: 84
Size: 400 mm
Rotor surface: Painted black
Electronics housing material: Die-cast aluminum, painted black
Impeller material: PA plastic, sheet-metal plate painted black
Support ring material: Stainless steel
Fan housing material: Sheet steel, galvanized and coated with black plastic (RAL 9005)
Number of blades: 5
Airflow direction: A
Direction of rotation: Clockwise, viewed toward rotor
Degree of protection: IP55
Insulation class: "F"
Moisture (F) / Environmental (H) protection class: H3
Max. permitted ambient temp. for motor (transport/storage): +80 °C
Min. permitted ambient temp. for motor (transport/storage): -40 °C
Installation position: Shaft horizontal or rotor on top; rotor on bottom on request
Condensation drainage holes: None
Mode: S1
Motor bearing: Ball bearing / (sealed)
Technical features: - Output 10 VDC, max. 10 mA - Operation and alarm display - Alarm relay - Motor current limitation - RS-485 MODBUS-RTU - Soft start - EEPROM write cycles: 100,000 maximum - Control input 0-10 VDC / PWM - Control interface with SELV potential safely disconnected from the mains - Overvoltage detection - Thermal overload protection for electronics/motor - Line undervoltage detection - Reverse polarity protection
EMC regulations: according to EN 50121-3-2
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system): <= 3,5 mA
Motor protection: Thermal switch auto reset, internally connected
with cable: Lateral
Protection class assignment: I; If a protective earth is connected by the customer|This component for installation may have several local protection classes. This information relates to this component’s basic design.|The final protection class is based on the component’s intended installation and connection.
Conformity with standards: EN 15085-1, CPC3; EN 45545-2, HL3; EN 50155; EN 61373, Cat. 1B
Approval: EAC
Comment: If voltage (e.g. 230 VAC) is passed through the alarm relay, the SELV signal wires lose their property of reinforced insulation, meaning they then have only basic insulation|The SELV property (reinforced insulation) is not lost when voltages of up to 110 VDC are passed through the alarm relay.
At PARTS HUB LLC, we supply not only EBM-PAPST products but also products from many other brands. We offer a wide range of products to provide the best solutions for our customers' needs. For more detailed information about the EBM-PAPST - W3G400-CK13-P3 product, please make a request immediately. If you would like to request a different product, request offer or send an email to info@usapartshub.com.
Request for quote EBM-PAPST W3G400-CK13-P3
Fields marked * are required to be filled.