W3G500-CA73-S1
Produttore: EBM-PAPST
(9 recensioni)
Descrizione:
EC axial fan - HyBlade
Weight: 15.8 kg
Motor size: 112
Size: 500 mm
Rotor surface: Painted black
Electronics housing material: Die-cast aluminum, painted black
Impeller material: PA plastic, sheet-metal plate painted black
Support ring material: Stainless steel
Fan housing material: Sheet steel, galvanized and coated with black plastic (RAL 9005)
Number of blades: 5
Airflow direction: A
Direction of rotation: Clockwise, viewed toward rotor
Degree of protection: IP55
Insulation class: "F"
Moisture (F) / Environmental (H) protection class: H3
Max. permitted ambient temp. for motor (transport/storage): +80 °C
Min. permitted ambient temp. for motor (transport/storage): -40 °C
Installation position: Shaft horizontal or rotor on top; rotor on bottom on request
Condensation drainage holes: None
Mode: S1
Motor bearing: Ball bearing / (sealed)
Technical features: - Output 10 VDC, max. 10 mA - Operation and alarm display - Alarm relay - Motor current limitation - RS-485 MODBUS-RTU - Soft start - EEPROM write cycles: 100,000 maximum - Control input 0-10 VDC / PWM - Control interface with SELV potential safely disconnected from the mains - Overvoltage detection - Thermal overload protection for electronics/motor - Line undervoltage detection
EMC regulations: according to EN 50121-3-2
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system): <= 3,5 mA
Motor protection: Thermal switch auto reset, internally connected
with cable: Lateral
Protection class assignment: I; If a protective earth is connected by the customer|This component for installation may have several local protection classes. This information relates to this component’s basic design.|The final protection class is based on the component’s intended installation and connection.
Conformity with standards: EN 15085-1, CPC3; EN 45545-2, HL3; EN 50155; EN 61373, Cat. 1B
Comment on CE: Ecodesign Directive 2009/125/EC + Fan Regulation (EC) No. 327/2011 does not apply, as use only in means of transport for transporting persons or goods.
Approval: EAC
Comment: If voltage (e.g. 230 VAC) is passed through the alarm relay, the SELV signal wires lose their property of reinforced insulation, meaning they then have only basic insulation|The SELV property (reinforced insulation) is not lost when voltages of up to 110 VDC are passed through the alarm relay.
Presso PARTS HUB LLC, forniamo non solo prodotti EBM-PAPST ma anche prodotti di molte altre marche. Offriamo una vasta gamma di prodotti per fornire le migliori soluzioni per le esigenze dei nostri clienti. Per ulteriori informazioni dettagliate sul prodotto EBM-PAPST - W3G500-CA73-S1, inviaci una richiesta immediata. Se desideri richiedere un prodotto diverso, richiedi un'offerta o invia un'email a info@usapartshub.com.
Richiesta di preventivo EBM-PAPST W3G500-CA73-S1
I campi contrassegnati con * sono obbligatori.